NOAC-E HFFR 5G1,5/1,5 300/500 V

Description

Description

NOAC-E stands for Non-Allergenic Cable and is a halogen free, HFFR insulated, aluminium screened, HFFR sheathed connecting cable with circular, multi stranded, bare copper conductors. The cable is designed according to HD 21.5 in applicable parts. The cables with numbers of conductors 2-5 and cross sections 1,5-2,5 mm² are for installation in conduits and cables with numbers of conductors 3-5 and cross section 0,75-2,5 mm² is only for class 1 appliances. The conductors have resistance according to EN 60228 class 5. The cores are cabled together and identified by colours according to HD 308. Together with the cable body a Tinned Drain wire is added. The screen of aluminium is turned with the AL-side inwards. The sheath is marked "Nexans GS Z1Z1 Semko". NOAC-E meets the requirements for CPR Dca-s2d2a2. The cable is certified by INTERTEK.

 

Restricted field of application

For installation in conduits: 2-5 conductors, 1,5-2,5 mm². Installation according to national wiring regulations.
Flexible cords 3-5 conductors, 0,75-2,5 mm². Only for class 1 appliances.

Certification

Certified by SEMKO.

Flammability class

CPR Dcas2d2a2.

Standard

CENELEC HD 21.5 where applicable.

Quality system

Certified according to ISO 9001, IRIS, ISO/TS 16949 and ISO 14001.

Characteristics

Characteristics

Construction characteristics

Construction characteristics

Colour
White
Conductor material
Bare copper
Insulation
HFFR
Armour type
Aluminium foil
Outer sheath
HFFR (Halogen Free Flame Retardant)
Halogen free
Yes

Dimensional characteristics

Dimensional characteristics

Number of cores
5
Conductor cross-section
1,5 mm²
Number of core wires (nb x mm Ø)
32 x 0.23 mm Ø
Conductor diameter
1,6 mm
Average insulation thickness
0,7 mm
Diameter over insulation
3,0 mm
Average sheath thickness
1,1 mm
Nominal outer diameter
10,4 mm
Approximate weight
165 kg/km

Electrical characteristics

Electrical characteristics

Max. DC resistance of the conductor at 20°C
13,3 Ohm/km
Rated Voltage Uo/U (Um)
300/500 V

Usage characteristics

Usage characteristics

Length
1000 m
Packaging
E8
Operating temperature, range
0 ... 70 °C

Resources

Resources

Selling & delivery Information

NOAC-E is delivered in specified lengths. The package is marked with manufacturer, type of cable, length and manufacturing date.

Declaration of Performance

  • Declaration of Performance n� : 1000801-SEGR
  • Certification Date : 05.02.19
  • AVCP (Assessment and Verification of Constancy of Performance) : System 3
  • Notified body : 366
  • Declared performance : Dca-s2,d2,a2

Contact us

Topics on which you wish to get more informations:

Required fields*

Please check your entry and try again.

An email address must contain a single @

Personal data protector

You have the right to object to the processing of your personal data and/or their use for direct marketing or commercial purposes

Thank you!

Thanks for contacting us. We will be in touch with you shortly.

Error

An error occurred. Please try again.

Close